Potential Transformer Potential Transformer

1500V:150V
Insulation systems: 105/130/155/180 degree are available.
Design to meet UL/CSA/TUV/VDE/CE and other safety requirements.
ROHS 2.0 Directive and (SVHC/REACH) are conformity.
Application field: Automatic control circuit

Share this:

Key Specifications


Application field:

1.Alarm Circuit

2.Automatic Control Circuit

3.Measurement Technology

 

Power Range: 50VA to 3000VA

Phase: Single

Input/Output: Customized

Insulation: up to 4kV (Hi-pot)

Sample Lead Time: 3~5 days
 Production Lead Time:3 Weeks  (Urgent order can be negotiated)
 Quantity:No MOQ Require

 

Specification Table

 

Power Regulation Temperature
Rise
Size(mm)   Power Regulation Temperature
Rise
Size(mm)
(VA) (%) L W H F/A×B   (VA) (%) L W H F/A×B
10VA 18.0% 60℃ 50 34 44 61   120VA 7.5% 60℃ 86.2 72 72 71×63
15VA 18.0% 60℃ 50 40 44 61   140VA 6.8% 60℃ 86.2 79 72 71×70
25VA 16.0% 60℃ 59.5 44 50.5 70.5   160VA 6.5% 60℃ 96 75 80.5 76×61
30VA 15.0% 60℃ 59.5 48.5 50.5 70.5   190VA 6.4% 60℃ 96 82 80.5 76×68
35VA 13.0% 60℃ 59.5 54 50.5 70.5   220VA 5.0% 65℃ 105 79 91 76×58
40VA 12.0% 60℃ 68.5 52 58.5 81.5   260VA 4.8% 65℃ 105 89 91 76×68
50VA 11.0% 60℃ 68.5 58 58.5 81.5   290VA 4.8% 65℃ 105 94 91 76×73
60VA 9.0% 60℃ 68.5 68 58.5 81.5   350VA 4.6% 65℃ 114 94 97.5 95×80
70VA 8.0% 60℃ 78.5 62 68.5 90   420VA 4.5% 65℃ 114 104 97.5 95×90
90VA 8.0% 60℃ 78.5 68 68.5 90   450VA 4.5% 65℃ 114 109 97.5 95×95

 

                                            

Process

EI Transformer Main Materials (IQC process)

All the material is inspected strictly with ISO9001:2015 quality program.

Core: appearance inspection and core loss test.

Copper wire: pinhole test and coat of adhesion test

 

 EI  Transformer Process

  • EI lamination has 0.35mm and 0.5mm thickness, material has Z11/H12/H14/H18/H50 of option.
  • The insulation for coil has 0.075/0.125mm thickness polyster film. 0.18/0.25mm DMD insulation paper and T410 Nomex paper. The brand of polyster film is DUPONT. The layers of overlap is deponds on the safety agent requirements.
  • Primary and Secondary winding wire is polyesterimid enameled, have 130/155/180/200degree for option.
  • Primary lead wire from type UL1617 double insulation for 600V voltage and 105 degree or UL3321 XLPE for 600V and 150degree.
  • Secondary lead wire from type UL1015 for 600V voltage and 105 degree.
  • Outer insulation is overlap 1 layer 0.075/0.125mm thickness polyester film or 0.18/0.25mm DMD insulation paper or T410 Nomex paper.

 

EI  Transformer Testing Items

  • Exciting current & core loss: 100% test
  • DC Resistance: 100% test
  • Layer insulation: 100% test
  • Loading test: 100% test
  • Hi-pot test: 100% test, but the time is only approx 10seconds for the production-run.
  • Aging test: Spot check, 10% of product quantity

 